instrument panel RENAULT TWINGO RS 2009 2.G Sequential Transmission Workshop Manual

Page 11 of 138

21B-11
MR-413-X44-21B000$177.mif
V2
Vdiag No: 04SEQUENTIAL GEARBOX
Fault finding - System operation21B
Lever operation:
–Each time the lever is moved, it returns to the “S” position automatically.
–When the vehicle has stopped and the engine is switched off and the key is in + after ignition feed position, lever
movements will only be registered if the driver depresses the brake pedal. In this case, all gears are available. The
number of gear changes possible is unlimited.
–When the vehicle has stopped and the engine is running, lever movements will only be registered if the driver
depresses the brake pedal. In this configuration, only gears N, 1, 2 and R are available.
–Position N only allows neutral to be engaged if the driver depresses the brake pedal.
–Position R enables reverse gear to be engaged. Reverse gear will only be engaged if the vehicle has stopped and
if the driver depresses the brake pedal. Engaging reverse when driving is prevented by the sequential gearbox
computer.
Display operation:
AUTO repeater
–As the display has an AUTO (A) symbol, it is possible to display the gear engaged at the same time as
AUTO mode.
Gear selection display
–Vehicle stopped or almost stopped: A new gear will only be displayed after confirmation that the gear has
really been engaged in the gearbox.
–Vehicle being driven: the change in the status of the display will depend on the driving mode selected:
In AUTO mode: simultaneous display of the AUTO mode and the gear engaged.
In MANUAL mode: engaged gear is displayed.
Display programming when gears cannot be engaged
–When a request would lead to engine overspeed or underspeed: the requested gear flashes then initial
gear reappears. Flashing ends after a delay.
–When there is a mechanical fault: application of the “retry” (1) program by the computer.
During retry: the requested gear flashes; then, the engaged gear is displayed on the instrument panel at
the end of the retry period. This program cannot be applied to neutral because the “N” position cannot
flash on the instrument panel; it remains lit.
(1) “RETRY”: If there is a mechanical fault engaging a gear (lower or higher), the computer will detect this
and will attempt to re-engage twice more; if this does not work, the requested gear will flash on the
instrument panel display and the gearbox will return to the gear used prior to this request.

Page 23 of 138

21B-23
MR-413-X44-21B000$354.mif
V2
Vdiag No: 04SEQUENTIAL GEARBOX
Fault finding - Fault summary table21B
*signal: signal
* FR: frontTool faultAssociated
DTCDiagnostic tool title
DF1445001 Coolant temperature multiplex signal
DF1455003 Invalid pedal position multiplex signal*
DF1464074 Torque no reduction multiplex signal
DF1475004 Invalid anticipated torque multiplex signal*
DF1484040 Invalid switch 2 multiplex signal
DF150C155 Instrument panel multiplex connection
DF1660932 Pressure sensor circuit
DF1754031 FR* wheel speed multiplex signal left
DF1764034 FR* wheel speed multiplex signal right
DF1800942 Hydraulic pump
DF1810919 Gear selection impossible
DF185C121 No ABS/ESP multiplex signal
DF1870949 Programming
DF1880701 System operation
DF2320604 Computer
DF2330605 Computer
DF2340603 Computer
DF2510715 Gearbox input speed
DF2520946 Pump relay
DF2540218 Clutch temperature
DF2562711 Erratic gear jumping
DF2570934 Slow loss of hydraulic pressure
DF2580935 Rapid loss of hydraulic pressure
DF2590867 Pressure accumulator
DF2620780 Auto-adaptive pattern
DF2635006 Instantaneous maximum torque multiplex signal
DF2650885 Computer

Page 58 of 138

21B-58
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF150
PRESENT
OR
STOREDINSTRUMENT PANEL MULTIPLEX CONNECTION
1.DEF : No signal
NOTESPriorities when dealing with a number of faults:
If fault DF062 Multiplex line fault is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the computer fault memory has been cleared, the
ignition has been switched off and on again and the engine has been started.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check the connection and condition of the connectors of components 120, 119 and 247.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Run a multiplex network test (see 88B, Multiplex).
If the multiplex network is correct, perform a fault finding of the instrument panel (see 83A, Instrument panel).
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF150

Page 70 of 138

21B-70
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF254
PRESENT
OR
STOREDCLUTCH TEMPERATURE
1.DEF : Clutch overheating
NOTESPriorities when dealing with a number of faults:
Deal with other faults declared present first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present when the clutch is used under severe conditions
(prolonged holding on a hill).
Special note:
–Instrument panel displays: “Sequential gearbox overheating”
–Fault warning light comes on.
–An engine speed wire fault or incorrect multiplex line value (speed equals 0) may
increase the occurrence of this fault.
Clear the stored fault and check that the clutch is not slipping by performing a road test, pulling away with a low
load then up or down an incline.
If the clutch slips, proceed in the following way:
–Pull away several times with low load and check parameter PR096 Clutch progressivity.
–If the fault is still present, replace the clutch.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF254

Page 83 of 138

21B-83
MR-413-X44-21B000$649.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of statuses
Vdiag No: 04
21B
ET013
GEAR ENGAGED
STATUS
DEFINITIONThis status ET013 indicates the gear engaged and corresponds to the gear displayed
on the instrument panel:
●1: 1st

2: 2nd

3: 3rd

4: 4th

5: 5th

N: Neutral
●R: Reverse
NOTESNone
Engine stopped, ignition on
Check the specification of status ET013 each time the gear lever is moved:
●Gears 1st to 5th: push the lever forwards for the next gear up and backwards for the next gear down and
check how status ET013 changes each time the gear lever moves.
●Position N (neutral): when status ET013 is "1", push the lever to the right and check that status ET013 is
"N".
●Gear R (reverse): check status ET013 changes to "R" after depressing the brake pedal, pushing the lever to
the right and then to the rear.
If status ET013 is not correct, refer to the interpretation of faults DF069 "Selection position circuit" and DF070
"Engaging position sensor circuit".
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
BVRJH1_V04_ET013

Page 85 of 138

21B-85
MR-413-X44-21B000$649.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of statuses
Vdiag No: 04
21B
ET028
HANDBRAKE
STATUS
DEFINITION"Engaged": the handbrake lever is raised.
"Released": the handbrake lever is in rest position.
NOTESUse the Wiring Diagrams Technical Note for New TWINGO.
Engine stopped, ignition on
Status ET028 indicates the position of the handbrake lever:
●"Engaged": the handbrake lever is raised.
●"Released": the handbrake lever is in rest position.
If status ET028 is incorrect, apply the procedure below.
Electrical check of the sensor
Run a multiplex network test (see 88B, multiplex).
Check the condition of the connections of component 156 and check that they are correctly connected.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Remove the handbrake switch.
Press the handbrake switch and check the insulation between connection 27A and earth.
If there is resistance, replace the handbrake switch.
Release the handbrake switch and check the continuity between the same connections.
If there is no continuity, replace the handbrake switch.
Check the condition of the connections of component 247 and check that they are correctly connected.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and the earth insulation on connection 27A between components 247 and 156.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
wiring: precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, perform a fault finding of the instrument panel (see 83A, Instrument panel).
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
BVRJH1_V04_ET028

Page 116 of 138

21B-116
MR-413-X44-21B000$767.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of parameters
Vdiag No: 04
21B
PR105
VEHICLE SPEED
PARAMETER
DEFINITIONThis parameter indicates the vehicle speed expressed in mph (km/h).
NOTESNone
Engine stopped, ignition on
PR105 = 0 km/h
If not correct, run fault finding on the ABS/ESP system (see 38C, Anti-lock braking system).
If the fault is still present, contact Techline.
Road test
Carry out a road test.
Check the consistency between the parameter value PR038 "Vehicle speed" in the domain of the ABS
computer and the speed displayed on the instrument panel.
If not correct, run fault finding on the ABS/ESP system (see 38C, Anti-lock braking system).
If the fault is still present, contact Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Deal with any other faults.
Clear the stored faults.
BVRJH1_V04_PR105